Your browser is not optimized for viewing this website.

More information »

TEC & Excelsior Training

Filter by Category



Our Classes

Resideo Honeywell Home - Melrose Park, IL

Free

with Gary Crosby

Calendar May 8, 2024 at 8 am

Overview of Honeywell Home products:

* Connected RedLINK Thermostats

* Honeywell Home Zoning

* T10+ Pro Smart

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Evolution Connex / Infinity Touch / Ion Controllers (hands-on) - NATE, FAD, & Elite hrs - North Aurora, IL

$60

with Ryan Hoger

Calendar May 9, 2024 at 8 am

This is a hands-on class with 2-3 students per system. The class will cover the functionality of the Evolution, Infinity, and Ion communicating touch screen controls. We will also discuss unique installation requirements as related to zoning systems, variable speed outdoor units, and modulating gas valves.

Topics will include:

-Wiring and commissioning

-Service settings and adjustments

-Wi-Fi setup

-Advanced, smart setback

-Real-time weather display

-Website management tool

-Mobile app usage

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.

NATE course ID# 8532-0002

NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Gas Heating Install, Gas Heating Service, Hydronics Install, Hydronics Service

 

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Will run

R-454B Installation Basics - FAD & Elite hrs - Melrose Park, IL

$15

with Ryan Hoger

Calendar May 13, 2024 at 8:30 am

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.

This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer.

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Full Course

A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, & Elite hrs - Lansing, IL

$75

with Dave Herman

Calendar May 14, 2024 at 8 am

Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.

This course will cover the 24/26 SEER fully variable units and the 5-stage units. Each student will also have the opportunity to practice connecting their mobile app to the condensing unit via Bluetooth.

These units are very efficient under part load conditions and use a variable speed inverter-driver scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.

These units feature low turndown (25-100%), high-efficiency, smooth start operation, and sound levels as low as 55dBA. The 5-stage units can can work with a communicating control for 5 stage operation or a standard thermostat for 2 stage functionality.  The fully varaible units must be used with a communicating control.

This class will specifically cover:

  • Proper application & installation 
  • Configuration of Infinity/Evolution control
  • Refrigerant charging procedure using controller
  • Required maintenance
  • Troubleshooting & Alarm Codes

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.

NATE course ID# 8532-0016

NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL

$75

with Dave Herman

Calendar May 15, 2024 at 8 am

This course offers a 1 hour familiarization of the troubleshooting and installation manuals followed by a 3 hour hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.

Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.

NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

R-454B Installation Basics - FAD & Elite hrs - South Bend, IN

$15

with Ryan Hoger

Calendar May 20, 2024 at 11:30 am

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.

This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer.

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Full Course

A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, & Elite hrs - Melrose Park, IL

$75

with Dave Herman

Calendar May 21, 2024 at 8 am

Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.

This course will cover the 24/26 SEER fully variable units and the 5-stage units. Each student will also have the opportunity to practice connecting their mobile app to the condensing unit via Bluetooth.

These units are very efficient under part load conditions and use a variable speed inverter-driver scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.

These units feature low turndown (25-100%), high-efficiency, smooth start operation, and sound levels as low as 55dBA. The 5-stage units can can work with a communicating control for 5 stage operation or a standard thermostat for 2 stage functionality.  The fully varaible units must be used with a communicating control.

This class will specifically cover:

  • Proper application & installation 
  • Configuration of Infinity/Evolution control
  • Refrigerant charging procedure using controller
  • Required maintenance
  • Troubleshooting & Alarm Codes

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.

NATE course ID# 8532-0016

NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

R-454B Installation Basics - FAD & Elite hrs - Melrose Park, IL

$15

with Ryan Hoger

Calendar May 22, 2024 at 8:30 am

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.

This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer.

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Will run





Forgot password?
Staff Log In