Filter by Subcategory
Bryant FAD
3 to 27 ton RTUs with Vane Axial Fans - NATE, FAD, & Elite hrs - Melrose Park, IL
with Neil Stoeger
Times are changing and the current code requirements for high IEERs are driving the market to use Staged Air Volume (SAV) in place of the traditional constant volume systems.
Smaller units using vane axial fans with ECM motors are standard now, so we will cover this type of RTU from Carrier (EcoBlue), Bryant (Axion), and ICP (X-Vane). This exclusive technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. This RTU includes the industry’s first belt-less direct-drive vane axial fan for rooftop units, a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors, and more.
Technicians need to know how to properly install, setup, and service all of these units, as they are now the standard RTUs in the market.
Topics covered include installation, start-up, and troubleshooting. We will discuss standard RTUs, ECM controlled SAV RTUs, airflow setup, vane axial fans, humidimizer, and economizers.
We will focus on Bryant, Carrier, & ICP SAV equipment in the 3 thru 27 ton range.
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0014
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, Elite, & ComEd hrs - Melrose Park, IL
with Dave Herman
This course offers familiarization of the troubleshooting and installation manuals followed by a hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-454B & R-410A refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Residential HVAC Service Fundamentals (multi-week class, hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL
with Ryan Hoger
This class meets a half day per week for 9 weeks. Class size is limited to 15 due to the hands-on nature. Much of the time will be spent in our live-fire lab which includes furnaces, boilers, A/C, etc.
Please bring hand tools, electrical meter (volts and amps), digital dual-port manometer, and R-410a gauges to class each week.
Module 1 - ABCs of Comfort
Module 2 - Basic Electrical Troubleshooting - read wiring diagrams, use a volt meter, measure amperage
Module 3 - Furnace Component Break Down plus Clean & Check - furnaces in the lab will be disassembled and re-assembled then we utilize O&M manuals to properly clean furnaces and check safeties
Module 4 - Furnace Troubleshooting - how to use a manometer or mag gauge to measure pressure, troubleshooting with a voltmeter, reading error codes, adjusting airflow, etc.
Module 5 - Boiler Service - component identification, basic piping, and how to clean a boiler
Module 6 - A/C and Heat Pump Charging & Maintenance - basic operation and troubleshooting, using refrigerant gauges and superheat to check charge arrangement
Module 7 - Ecobee Smart Thermostats - install, setup, and programming
Module 8 - Ductless Mini-split Installation and Service
Module 9 - Indoor Air Quality (IAQ) Basics – Filtration, Evolution/Infinity air purifier, UV lights, PCO duct air purifiers, and bi-polar ionizers for functions, installation, and maintenance
Must attend at least 6 modules to earn 24 "FAD Distributor" or "Elite Distributor" hours.
Each module earns 4 NATE hours (except module 1) and credit can be awarded individually for each module. Note: smart stat module is only 3 NATE hours.
NATE course IDs:
Electrical #8532-0007
Furnace Clean #8532-0010
Furnace Service #8532-0003
Boiler #8532-0008
A/C & HP #8532-0001
Smart stats #8532-0017
Ductless #8532-0022
IAQ #8532-0012
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, Elite, & ComEd hrs - Melrose Park, IL
with Dave Herman
This course offers familiarization of the troubleshooting and installation manuals followed by a hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-454B & R-410A refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
3 to 27 ton RTUs with Vane Axial Fans - NATE, FAD, & Elite hrs - New Berlin, WI
with Neil Stoeger
Times are changing and the current code requirements for high IEERs are driving the market to use Staged Air Volume (SAV) in place of the traditional constant volume systems.
Smaller units using vane axial fans with ECM motors are standard now, so we will cover this type of RTU from Carrier (EcoBlue), Bryant (Axion), and ICP (X-Vane). This exclusive technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. This RTU includes the industry’s first belt-less direct-drive vane axial fan for rooftop units, a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors, and more.
Technicians need to know how to properly install, setup, and service all of these units, as they are now the standard RTUs in the market.
Topics covered include installation, start-up, and troubleshooting. We will discuss standard RTUs, ECM controlled SAV RTUs, airflow setup, vane axial fans, humidimizer, and economizers.
We will focus on Bryant, Carrier, & ICP SAV equipment in the 3 thru 27 ton range.
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0014
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, Elite, & ComEd hrs - Melrose Park, IL
with Dave Herman
Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.
This course will cover the fully variable R-454B & R-410A units, as well as the 5-stage R-410A units.
These units are very efficient under part load conditions and use variable speed inverter-driven scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.
These units feature low turndown, high-efficiency, smooth start operation, and sound levels as low as 55dBA. The fully varaible units should be used with a communicating control.
This class will specifically cover:
- Proper application & installation
- Configuration of Infinity/Evolution control
- Refrigerant charging procedure using controller
- Required maintenance
- Troubleshooting & Alarm Codes
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.
NATE course ID# 8532-0016
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Carrier/Bryant/ICP Crossover Inverter Heat Pump Install & Service – NATE, FAD, & ComEd hrs - Melrose Park, IL
with Andy Sias
OVERVIEW:This training course provides the participants with an overview of Carrier/Bryant 37MU and Heil/Day&Night D5CU Crossover units which allow the usage of a horizontal discharge mini-split inverter with a standard furnace or air handler fan coil. The course will include installation requirements, operating characteristics and a general overview of service and troubleshooting procedures.
WHO SHOULD ATTEND:The target audience includes HVAC technicians and installers. Attendees should have a general understanding of air conditioning systems, refrigerants, installation and service procedures.
REQUIRED TOOLS: electrical meter and basic hand-tools
OUTLINE:
- Introduction of product (including models, capacities, voltages, etc.)
- Application of R-454B refrigerant
- Installation requirements and procedures
- Operating characteristics
- Fault codes
- Servicing and Diagnostic procedures
- Refrigerant piping lengths and charging procedures
- Installation wiring (standard thermostat or communicating)
This classes qualifies for 4 "FAD Distributor" or "Elite Distributor" hours for the dealer and 4 NATE hours for the technician
NATE course ID# 8532-0028, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service, Low GWP Refrigerants
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, Elite, & ComEd hrs - Lansing, IL
with Dave Herman
This course offers familiarization of the troubleshooting and installation manuals followed by a hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-454B & R-410A refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run