3 to 27 ton RTUs with Vane Axial Fans - NATE, FAD, & Elite hrs - Melrose Park, IL
with Neil Stoeger
Times are changing and the current code requirements for high IEERs are driving the market to use Staged Air Volume (SAV) in place of the traditional constant volume systems.
Smaller units using vane axial fans with ECM motors are standard now, so we will cover this type of RTU from Carrier (EcoBlue), Bryant (Axion), and ICP (X-Vane). This exclusive technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. This RTU includes the industry’s first belt-less direct-drive vane axial fan for rooftop units, a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors, and more.
Technicians need to know how to properly install, setup, and service all of these units, as they are now the standard RTUs in the market.
Topics covered include installation, start-up, and troubleshooting. We will discuss standard RTUs, ECM controlled SAV RTUs, airflow setup, vane axial fans, humidimizer, and economizers.
We will focus on Bryant, Carrier, & ICP SAV equipment in the 3 thru 27 ton range.
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0014
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
R-454B Installation Basics - FAD & Elite hrs - North Aurora, IL
with Ryan Hoger
We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.
This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
R-454B Installation Basics - FAD & Elite hrs - Libertyville, IL
with Ryan Hoger
We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.
This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Aeroseal Duct Sealing with HomeSeal (hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL
with Ryan Hoger
Note: There is no charge for dealers who wish to attend the Day 1 portion as a refresher. Contact rhoger@tecmungo.com for FREE REGISTRATION CODE. Make sure your HomeSeal machine is clean and operational BEFORE you bring it to class.
The training will be two days for new dealers. Day 1 will be at TEC and Day 2 will be on-site at a home. Each dealer should have their 2-man Aeroseal install crew attend both days. It is also suggested that your retail sales person (or whomever will be quoting Aeroseal systems) attend the morning portion of the 1st day at a minimum.
Day 1 Morning - Classroom training session
Day 1 Afternoon - Three dealers in the TEC lab each using their own HomeSeal machines simultaneously to seal the small duct systems that we have in the lab. The dealer needs to bring ALL of their Aeroseal equipment (machine, tablet, sealant, foam, air compressor, dryer, extension cords, EVERYTHING).
Day 2 All day - Single dealer doing a full seal at the residential home of their choice (preferably one of their own employees not a client). New dealers should already have been contacted about scheduling this date. If an existing dealer needs a field training refresher please contact the instructor to schedule.
Lunch will provided on the 1st day at the classroom.
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0006 NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Gas Heating Service, Gas Heating Install
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
Gas Furnace 102: Service & Troubleshooting (hands-on) - NATE, FAD, & Elite hrs - Lansing, IL
with Dave Herman
Students MUST first attend Gas Furnace 101 or have instructor approval to skip into this more advanced class.
This course offers a 1 hour familiarization of the troubleshooting and installation manuals followed by a 3 hour hands-on training session. The lab work will include start-up and troubleshooting procedures of residential gas furnaces. Students will be working on fully function systems in the lab area.
Please bring hand tools, volt or multi-meter, and manometer (or magnahelic).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0003
NATE credit received through this course is associated with the following specialties: Gas Heating Install, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL
with Dave Herman
This course offers a 1 hour familiarization of the troubleshooting and installation manuals followed by a 3 hour hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Carrier Ductless Mini-split Installation & Service – NATE & FAD hrs - Melrose Park, IL
with Andy Sias
OVERVIEW:This training course provides the participants with an overview of 1-to-1 Split and Multi products including installation requirements, operating characteristics and a general overview of service and troubleshooting procedures.
WHO SHOULD ATTEND:The target audience includes HVAC technicians and installers. Attendees should have a general understanding of air conditioning systems, refrigerants, installation and service procedures.
OUTLINE:
- Introduction of product (including models, capacities, voltages, etc.)
- Application of R-410a refrigerant
- Installation requirements and procedures
- Operating characteristics
- Fault codes
- Servicing and Diagnostic procedures
- Refrigerant piping lengths and charging procedures
- Installation wiring (Single-split and multi)
This classes qualifies for 4 "FAD Distributor" hours for the dealer and 4 NATE hours for the technician.
NATE course ID# 8532-0022, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Certified HVAC Pro, Efficiency Analyst, Gas Heating Install, Gas Heating Service, HVAC Performance Verifier, Light Comm Refrig Install, Light Comm Refrig Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
R-454B Installation Basics - FAD & Elite hrs - Loves Park, IL
with Ryan Hoger
We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.
This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.