Filter by Category
Distributor
in Bryant FAD
R-454B Installation Basics - FAD & Elite hrs - South Bend, IN
with Ryan Hoger

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.
This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer. Each student will also receive a reverse thread adapter which is required for A2L refrigerant cylinders.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
Residential Zoning System Design & Installation - FAD & Elite hrs - North Aurora, IL
with Ryan Hoger

PREREQUISITE: Students must have attended the half day Infinity/Evolution/Ion non-zoning class in the past 3 years.
The class will cover the design, setup, and operation of the Evolution, Infinity, and Ion communicating zoning system controls.
Topics will include:
-Zone layout
-Damper sizing and selection
-Wiring and commissioning
-Service settings and adjustments
- Dos and Don'ts
This classes qualifies for 3 "FAD Distributor" or "Elite Distributor" hours for the dealer.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
3 to 27 ton RTUs with Vane Axial Fans - NATE, FAD, & Elite hrs - Melrose Park, IL
with Neil Stoeger

Times are changing and the current code requirements for high IEERs are driving the market to use Staged Air Volume (SAV) in place of the traditional constant volume systems.
Smaller units using vane axial fans with ECM motors are standard now, so we will cover this type of RTU from Carrier (EcoBlue), Bryant (Axion), and ICP (X-Vane). This exclusive technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. This RTU includes the industry’s first belt-less direct-drive vane axial fan for rooftop units, a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors, and more.
Technicians need to know how to properly install, setup, and service all of these units, as they are now the standard RTUs in the market.
Topics covered include installation, start-up, and troubleshooting. We will discuss standard RTUs, ECM controlled SAV RTUs, airflow setup, vane axial fans, humidimizer, and economizers.
We will focus on Bryant, Carrier, & ICP SAV equipment in the 3 thru 27 ton range.
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0014
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
R-454B Installation Basics - FAD & Elite hrs - Libertyville, IL
with Ryan Hoger

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.
This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer. Each student will also receive a reverse thread adapter which is required for A2L refrigerant cylinders.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
Duct & Envelope Tightness (DET) Certification (hands-on) - NATE, FAD, Elite, & BPI hrs - Melrose Park, IL
with Joe Konopacki

Details and registration for this class are at: https://www.insightpsinc.com/bpi-building-analyst-training/
This classes qualifies for 8 NATE hours and 8 BPI hours for the technician plus 8 "FAD Distributor" or "Elite Distributor" hours for the dealer.