Filter by Category
ComEd Heat Pump
Carrier 38MURA Crossover Inverter Installation & Service – FAD & ComEd hrs - Melrose Park, IL
with Andy Sias

OVERVIEW:This training course provides the participants with an overview of 38MURA Crossover unit which allows the usage of a horizontal discharge mini-split inverter with a standard furnace or fan coil. The course will include installation requirements, operating characteristics and a general overview of service and troubleshooting procedures.
WHO SHOULD ATTEND:The target audience includes HVAC technicians and installers. Attendees should have a general understanding of air conditioning systems, refrigerants, installation and service procedures.
REQUIRED TOOLS: electrical meter and basic hand-tools
OUTLINE:
- Introduction of product (including models, capacities, voltages, etc.)
- Application of R-410a refrigerant
- Installation requirements and procedures
- Operating characteristics
- Fault codes
- Servicing and Diagnostic procedures
- Refrigerant piping lengths and charging procedures
- Installation wiring (standard thermostat or communicating)
This classes qualifies for 4 "FAD Distributor" hours for the dealer.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Carrier Ductless Mini-split Installation & Service – NATE, FAD, & ComEd hrs - Melrose Park, IL
with Andy Sias

OVERVIEW:This training course provides the participants with an overview of 1-to-1 mini-split products including installation requirements, operating characteristics and a general overview of service and troubleshooting procedures.
WHO SHOULD ATTEND:The target audience includes HVAC technicians and installers. Attendees should have a general understanding of air conditioning systems, refrigerants, installation and service procedures.
REQUIRED TOOLS: torque wrench, R-410A flaring tool, reemer, pipe cutter, 2 adjustable wrenches, electrical meter, and basic hand-tools
OUTLINE:
- Introduction of product (including models, capacities, voltages, etc.)
- Application of R-410a refrigerant
- Installation requirements and procedures
- Operating characteristics
- Fault codes
- Servicing and Diagnostic procedures
- Refrigerant piping lengths and charging procedures
- Installation wiring
This classes qualifies for 4 "FAD Distributor" hours for the dealer and 4 NATE hours for the technician.
NATE course ID# 8532-0022, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Certified HVAC Pro, Efficiency Analyst, Gas Heating Install, Gas Heating Service, HVAC Performance Verifier, Light Comm Refrig Install, Light Comm Refrig Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, Elite, & ComEd hrs - Melrose Park, IL
with Dave Herman

Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.
This course will cover the 24/26 SEER fully variable units and the 5-stage units. Each student will also have the opportunity to practice connecting their mobile app to the condensing unit via Bluetooth.
These units are very efficient under part load conditions and use a variable speed inverter-driver scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.
These units feature low turndown (25-100%), high-efficiency, smooth start operation, and sound levels as low as 55dBA. The 5-stage units can can work with a communicating control for 5 stage operation or a standard thermostat for 2 stage functionality. The fully varaible units must be used with a communicating control.
This class will specifically cover:
- Proper application & installation
- Configuration of Infinity/Evolution control
- Refrigerant charging procedure using controller
- Required maintenance
- Troubleshooting & Alarm Codes
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.
NATE course ID# 8532-0016
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
Carrier Ductless Mini-split Installation & Service – NATE, FAD, & ComEd hrs - Melrose Park, IL
with Andy Sias

OVERVIEW:This training course provides the participants with an overview of 1-to-1 mini-split products including installation requirements, operating characteristics and a general overview of service and troubleshooting procedures.
WHO SHOULD ATTEND:The target audience includes HVAC technicians and installers. Attendees should have a general understanding of air conditioning systems, refrigerants, installation and service procedures.
REQUIRED TOOLS: torque wrench, R-410A flaring tool, reemer, pipe cutter, 2 adjustable wrenches, electrical meter, and basic hand-tools
OUTLINE:
- Introduction of product (including models, capacities, voltages, etc.)
- Application of R-410a refrigerant
- Installation requirements and procedures
- Operating characteristics
- Fault codes
- Servicing and Diagnostic procedures
- Refrigerant piping lengths and charging procedures
- Installation wiring
This classes qualifies for 4 "FAD Distributor" hours for the dealer and 4 NATE hours for the technician.
NATE course ID# 8532-0022, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Certified HVAC Pro, Efficiency Analyst, Gas Heating Install, Gas Heating Service, HVAC Performance Verifier, Light Comm Refrig Install, Light Comm Refrig Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, Elite, & ComEd - South Bend, IN
with Dave Herman

Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.
This course will cover the 24/26 SEER fully variable units and the 5-stage units. Each student will also have the opportunity to practice connecting their mobile app to the condensing unit via Bluetooth.
These units are very efficient under part load conditions and use a variable speed inverter-driver scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.
These units feature low turndown (25-100%), high-efficiency, smooth start operation, and sound levels as low as 55dBA. The 5-stage units can can work with a communicating control for 5 stage operation or a standard thermostat for 2 stage functionality. The fully varaible units must be used with a communicating control.
This class will specifically cover:
- Proper application & installation
- Configuration of Infinity/Evolution control
- Refrigerant charging procedure using controller
- Required maintenance
- Troubleshooting & Alarm Codes
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.
NATE course ID# 8532-0016
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, Elite, & ComEd hrs - Melrose Park, IL
with Dave Herman

This course offers familiarization of the troubleshooting and installation manuals followed by a hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, Elite, & ComEd - North Aurora, IL
with Dave Herman

Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.
This course will cover the 24/26 SEER fully variable units and the 5-stage units. Each student will also have the opportunity to practice connecting their mobile app to the condensing unit via Bluetooth.
These units are very efficient under part load conditions and use a variable speed inverter-driver scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.
These units feature low turndown (25-100%), high-efficiency, smooth start operation, and sound levels as low as 55dBA. The 5-stage units can can work with a communicating control for 5 stage operation or a standard thermostat for 2 stage functionality. The fully varaible units must be used with a communicating control.
This class will specifically cover:
- Proper application & installation
- Configuration of Infinity/Evolution control
- Refrigerant charging procedure using controller
- Required maintenance
- Troubleshooting & Alarm Codes
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.
NATE course ID# 8532-0016
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, Elite, & ComEd hrs - Melrose Park, IL
with Dave Herman

This course offers familiarization of the troubleshooting and installation manuals followed by a hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.