Your browser is not optimized for viewing this website.

More information »

TEC & Excelsior Training

Filter by Category



Our Classes

R-454B Installation Basics - FAD & Elite hrs - North Aurora, IL

$15

with Ryan Hoger

Calendar Apr 1, 2024 at 8:30 am

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.

This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer.

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

RTUs: Repair or Replace… or Enhance? - PE PDHs, FAD, & Elite hrs - Melrose Park, IL

$95

with Ryan Hoger

Calendar Apr 3, 2024 at 8 am

Packaged roof top units (RTUs) are used to easily and effectively heat and cool more than 50% of all commercial buildings, but how long do they last out in the environment in the northern climates? Should you spend money to repair one when it finally fails or should you replace it with a new unit? Or should replace it before it fails? Are there ways to save energy on the existing or the new unit?, This course will use proven methods and easy to use (and free) software tools help to quantify the economic value of a repair, a new unit, or an energy conservation measure.

OPTIONAL: PLEASE BRING YOUR LAPTOP TO CLASS TO INSTALL AND RUN THESE SOFTWARE TOOLS.

Learning Objectives:

As a result of this training, participants will be able to:

1. Install and use free software to analyze the economics of RTU replacements and improvements

2. Understand AHRI efficiency ratings for packaged RTUs

3. Know the RTU related requirements of the International Energy Conservation Code (IECC) 2015 & 2018, which are the current codes in Wisconsin, Illinois, and other states

4. Select the appropriate RTU controls and accessories to maximize performance and efficiency

5. Be able to describe technologies such as economizers, demand controlled ventilation, staged air volume, and energy recovery ventilation

This classes qualifies for 7 PDHs for an engineer plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer. 

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Will run

Economizer Basics & Setup for Honeywell JADE & Siemens Climatix-ECO (hands-on) - NATE, FAD, & Elite hrs - South Bend, IN

$45

with Ryan Hoger

Calendar Apr 4, 2024 at 8 am

Economizers have been increasingly required by energy code but many technicians have a set it and forget attitude about these devices. Sometimes they can be simple applications, but other times things can bite you.

This course will examine the following:

1. Technology Overview

2. Dry bulb vs. Enthalpy

3. IECC Code Requirements (including local law)

4. Typical Energy Savings

5. CO2-based Demand Controlled Ventilation (DCV)

6. Honeywell JADE Economizer Controller Wiring

7. Hands-on Setup and Configuration of JADE on the workbench

8. Overview of MicroMetl's Siemens Climatix-ECO Controller

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.

NATE course ID# 8532-0009

NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Gas Heat Install, Gas Heat Service, Light Commercial Install, Light Commercial Service

 

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Will run

7.5 to 28 ton RTUs with Staged Air Volume (ECM & VFD) - Melrose Park, IL

$60

with Dave Herman

Calendar Apr 5, 2024 at 8 am

Times are changing and the current code requirements for high IEERs are driving the market to use ECMs and VFDs for Staged Air Volume (SAV) in place of the traditional constant volume systems.

Topics covered include components, installation, start-up, programming, and troubleshooting. We will discuss Vane-Axial RTUs and speed setup, VFD controlled RTUs and drive setup, belt and pulley alignment and tensioning, humidimizer, EnergyX ERV, and economizers.

We will focus on Bryant, Carrier, & ICP SAV equipment in the 7.5 thru 28 ton range.

 

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Will run

R-454B Installation Basics - FAD & Elite hrs - Lansing, IL

$15

with Ryan Hoger

Calendar Apr 8, 2024 at 8:30 am

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.

This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer.

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

DX Piping for Commercial Split Systems Systems - PDH - Melrose Park, IL
Registration Unavailable

DX Piping for Commercial Split Systems Systems - PDH - Melrose Park, IL

$55

with Doug Bare

Students will learn how to size refrigerant piping for commercial DX split systems including fundamental topics such as: line length, vertical height restraints, speed risers, double suction risers, hot gas bypass, etc. Additionally, special considerations for DX piping associated with variable capacity Digital Scroll compressors will also be covered. 

This class qualifies for (4) four hours of continuing education for Illinois and Wisconsin Professional Engineers.

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.

A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL

$75

with Dave Herman

Calendar Apr 10, 2024 at 8 am

This course offers a 1 hour familiarization of the troubleshooting and installation manuals followed by a 3 hour hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.

Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.

NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Full Course

A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, & Elite hrs - Melrose Park, IL

$70

with Dave Herman

Calendar Apr 11, 2024 at 8 am

Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.

This course will cover the 24/26 SEER fully variable units and the 5-stage units. Each student will also have the opportunity to practice connecting their mobile app to the condensing unit via Bluetooth.

These units are very efficient under part load conditions and use a variable speed inverter-driver scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.

These units feature low turndown (25-100%), high-efficiency, smooth start operation, and sound levels as low as 55dBA. The 5-stage units can can work with a communicating control for 5 stage operation or a standard thermostat for 2 stage functionality.  The fully varaible units must be used with a communicating control.

This class will specifically cover:

  • Proper application & installation 
  • Configuration of Infinity/Evolution control
  • Refrigerant charging procedure using controller
  • Required maintenance
  • Troubleshooting & Alarm Codes

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.

NATE course ID# 8532-0016

NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Full Course




Forgot password?
Staff Log In