Filter by Category
Our Classes
Evolution Connex / Infinity Touch / Ion Controllers (hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL
with Ryan Hoger
This is a hands-on class with 2-3 students per system. The class will cover the functionality of the Evolution, Infinity, and Ion communicating touch screen controls. We will also discuss unique installation requirements as related to zoning systems, variable speed outdoor units, and modulating gas valves.
Topics will include:
-Wiring and commissioning
-Service settings and adjustments
-Wi-Fi setup
-Advanced, smart setback
-Real-time weather display
-Website management tool
-Mobile app usage
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0002
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Gas Heating Install, Gas Heating Service, Hydronics Install, Hydronics Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Carrier/Bryant/ICP Crossover Inverter Heat Pump Install & Service – NATE, FAD, & ComEd hrs - Loves Park, IL
with Andy Sias
OVERVIEW:This training course provides the participants with an overview of Carrier/Bryant 37MU and Heil/Day&Night D5CU Crossover units which allow the usage of a horizontal discharge mini-split inverter with a standard furnace or air handler fan coil. The course will include installation requirements, operating characteristics and a general overview of service and troubleshooting procedures.
WHO SHOULD ATTEND:The target audience includes HVAC technicians and installers. Attendees should have a general understanding of air conditioning systems, refrigerants, installation and service procedures.
OUTLINE:
- Introduction of product (including models, capacities, voltages, etc.)
- Application of R-454B refrigerant
- Installation requirements and procedures
- Operating characteristics
- Fault codes
- Servicing and Diagnostic procedures
- Refrigerant piping lengths and charging procedures
- Installation wiring (standard thermostat or communicating)
This classes qualifies for 3 "FAD Distributor" or "Elite Distributor" hours for the dealer and 3 NATE hours for the technician
NATE course ID# 8532-0028, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service, Low GWP Refrigerants
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Bradford White Tankless Level II & III - Melrose Park, IL
with Jack Brody
Registration for this class is at: https://app.smartsheet.com/b/form/e149b38bf9394aaab3da9cc320a0d74a
Join us for a hands-on training session focused on Infiniti GS-GR systems. This program is designed specifically for contractors looking to deepen their knowledge and skillset with Level II and Level III certification.
Level II is limited to 25 participants
Level III is limited to 25 participants
Each company may register up to 3 attendees for Level III
Level II must be completed before attending Level III
Instructor: Jack Brody of Bradford White
This classes qualifies for 4 Illinois Plumbing CEUs
Level III participants will receive a GS-GR parts kit free of charge (one per company)
Evolution Connex / Infinity Touch / Ion Controllers (hands-on) - NATE, FAD, & Elite hrs - North Aurora, IL
with Ryan Hoger
This is a hands-on class with 2-3 students per system. The class will cover the functionality of the Evolution, Infinity, and Ion communicating touch screen controls. We will also discuss unique installation requirements as related to zoning systems, variable speed outdoor units, and modulating gas valves.
Topics will include:
-Wiring and commissioning
-Service settings and adjustments
-Wi-Fi setup
-Advanced, smart setback
-Real-time weather display
-Website management tool
-Mobile app usage
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0002
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Gas Heating Install, Gas Heating Service, Hydronics Install, Hydronics Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
Duct & Envelope Tightness (DET) Certification (hands-on) - NATE, FAD, Elite, & BPI hrs - Melrose Park, IL
with Joe Konopacki
Details and registration for this class are at: https://www.eventbrite.com/e/duct-envelope-tightness-det-verifier-earn-8-bpi-8-nate-ces-melrose-tickets-1975340504624
This classes qualifies for 8 NATE hours and 8 BPI hours for the technician plus 8 "FAD Distributor" or "Elite Distributor" hours for the dealer.
3 to 27 ton RTUs with Vane Axial Fans - NATE, FAD, & Elite hrs - Melrose Park, IL
with Neil Stoeger
Times are changing and the current code requirements for high IEERs are driving the market to use Staged Air Volume (SAV) in place of the traditional constant volume systems.
Smaller units using vane axial fans with ECM motors are standard now, so we will cover this type of RTU from Carrier (EcoBlue), Bryant (Axion), and ICP (X-Vane). This exclusive technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. This RTU includes the industry’s first belt-less direct-drive vane axial fan for rooftop units, a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors, and more.
Technicians need to know how to properly install, setup, and service all of these units, as they are now the standard RTUs in the market.
Topics covered include installation, start-up, and troubleshooting. We will discuss standard RTUs, ECM controlled SAV RTUs, airflow setup, vane axial fans, humidimizer, and economizers.
We will focus on Bryant, Carrier, & ICP SAV equipment in the 3 thru 27 ton range.
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0014
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
Residential HVAC Service Fundamentals (multi-week class, hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL
with Ryan Hoger
This class meets a half day per week for 9 weeks. Class size is limited to 15 due to the hands-on nature. Much of the time will be spent in our live-fire lab which includes furnaces, boilers, A/C, etc.
Please bring hand tools, electrical meter (volts and amps), digital dual-port manometer, and R-410a gauges to class each week.
Module 1 - ABCs of Comfort
Module 2 - Basic Electrical Troubleshooting - read wiring diagrams, use a volt meter, measure amperage
Module 3 - Furnace Component Break Down plus Clean & Check - furnaces in the lab will be disassembled and re-assembled then we utilize O&M manuals to properly clean furnaces and check safeties
Module 4 - Furnace Troubleshooting - how to use a manometer or mag gauge to measure pressure, troubleshooting with a voltmeter, reading error codes, adjusting airflow, etc.
Module 5 - Boiler Service - component identification, basic piping, and how to clean a boiler
Module 6 - A/C and Heat Pump Charging & Maintenance - basic operation and troubleshooting, using refrigerant gauges and superheat to check charge arrangement
Module 7 - Ecobee Smart Thermostats - install, setup, and programming
Module 8 - Ductless Mini-split Installation and Service
Module 9 - Indoor Air Quality (IAQ) Basics – Filtration, Evolution/Infinity air purifier, UV lights, PCO duct air purifiers, and bi-polar ionizers for functions, installation, and maintenance
Must attend at least 6 modules to earn 24 "FAD Distributor" or "Elite Distributor" hours.
Each module earns 4 NATE hours (except module 1) and credit can be awarded individually for each module. Note: smart stat module is only 3 NATE hours.
NATE course IDs:
Electrical #8532-0007
Furnace Clean #8532-0010
Furnace Service #8532-0003
Boiler #8532-0008
A/C & HP #8532-0001
Smart stats #8532-0017
Ductless #8532-0022
IAQ #8532-0012
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
3 to 27 ton RTUs with Vane Axial Fans - NATE, FAD, & Elite hrs - New Berlin, WI
with Neil Stoeger
Times are changing and the current code requirements for high IEERs are driving the market to use Staged Air Volume (SAV) in place of the traditional constant volume systems.
Smaller units using vane axial fans with ECM motors are standard now, so we will cover this type of RTU from Carrier (EcoBlue), Bryant (Axion), and ICP (X-Vane). This exclusive technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. This RTU includes the industry’s first belt-less direct-drive vane axial fan for rooftop units, a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors, and more.
Technicians need to know how to properly install, setup, and service all of these units, as they are now the standard RTUs in the market.
Topics covered include installation, start-up, and troubleshooting. We will discuss standard RTUs, ECM controlled SAV RTUs, airflow setup, vane axial fans, humidimizer, and economizers.
We will focus on Bryant, Carrier, & ICP SAV equipment in the 3 thru 27 ton range.
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0014
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.