Filter by Category
Our Classes
Economizer Basics & Setup for Honeywell JADE & Siemens Climatix-ECO (hands-on) - NATE, FAD, & Elite hrs - Libertyville, IL
with Ryan Hoger

Economizers have been increasingly required by energy code but many technicians have a set it and forget attitude about these devices. Sometimes they can be simple applications, but other times things can bite you.
This course will examine the following:
1. Technology Overview
2. Dry bulb vs. Enthalpy
3. IECC Code Requirements (including local law)
4. Typical Energy Savings
5. CO2-based Demand Controlled Ventilation (DCV)
6. Honeywell JADE Economizer Controller Wiring
7. Hands-on Setup and Configuration of JADE on the workbench
8. Overview of MicroMetl's Siemens Climatix-ECO Controller
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0009
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Gas Heat Install, Gas Heat Service, Light Commercial Install, Light Commercial Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
R-454B Installation Basics - FAD & Elite hrs - Melrose Park, IL
with Ryan Hoger

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.
This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer. Each student will also receive a reverse thread adapter which is required for A2L refrigerant cylinders.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, & Elite hrs - Lansing, IL
with Dave Herman

This course offers familiarization of the troubleshooting and installation manuals followed by a hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Advanced Combustion Safety (hands-on) - NATE, FAD, Elite, & BPI hrs - Melrose Park, IL
with Joe Konopacki
Details and registration for this class are at: https://www.eventbrite.com/e/advanced-combustion-safety-4-bpi-ceus-8-nate-ceus-melrose-park-il-tickets-1131158107349
This classes qualifies for 8 NATE hours and 4 BPI hours for the technician plus 8 "FAD Distributor" or "Elite Distributor" hours for the dealer.
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL
with Dave Herman

This course offers familiarization of the troubleshooting and installation manuals followed by a hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
R-454B Installation Basics - FAD & Elite hrs - Lansing, IL
with Ryan Hoger

We will cover the A2L transition for residential split systems and small tonnage packaged RTUs. Specific topics covered include transition timeline, flammability, refrigerant properties, equipment differences compared to R-410A, technician tools, and dissipation system wiring and troubleshooting.
This classes qualifies for 2 "FAD Distributor" or "Elite Distributor" hours for the dealer. Each student will also receive a reverse thread adapter which is required for A2L refrigerant cylinders.
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
Residential HVAC Service Fundamentals (multi-week class, hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL
with Ryan Hoger

This class meets a half day per week for 9 weeks. Class size is limited to 15 due to the hands-on nature. Much of the time will be spent in our live-fire lab which includes furnaces, boilers, A/C, etc.
Please bring hand tools, electrical meter (volts and amps), digital dual-port manometer, and R-410a gauges to class each week.
Module 1 - ABCs of Comfort
Module 2 - Basic Electrical Troubleshooting - read wiring diagrams, use a volt meter, measure amperage
Module 3 - Furnace Component Break Down plus Clean & Check - furnaces in the lab will be disassembled and re-assembled then we utilize O&M manuals to properly clean furnaces and check safeties
Module 4 - Furnace Troubleshooting - how to use a manometer or mag gauge to measure pressure, troubleshooting with a voltmeter, reading error codes, adjusting airflow, etc.
Module 5 - Boiler Service - component identification, basic piping, and how to clean a boiler
Module 6 - Ecobee Smart Thermostats - install, setup, and programming
Module 7 - A/C and Heat Pump Charging & Maintenance - basic operation and troubleshooting, using refrigerant gauges and superheat to check charge arrangement
Module 8 - Ductless Mini-split Installation and Service
Module 9 - Indoor Air Quality (IAQ) Basics – Filtration, Evolution/Infinity air purifier, UV lights, PCO duct air purifiers, and bi-polar ionizers for functions, installation, and maintenance
Must attend at least 6 modules to earn 24 "FAD Distributor" or "Elite Distributor" hours.
Each module earns 4 NATE hours (except module 1) and credit can be awarded individually for each module. Note: smart stat module is only 3 NATE hours.
NATE course IDs:
Electrical #8532-0007
Furnace Clean #8532-0010
Furnace Service #8532-0003
Boiler #8532-0008
Smart stats #8532-0017
A/C & HP #8532-0001
Ductless #8532-0022
IAQ #8532-0012
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Carrier Ductless Mini-split Installation & Service – NATE & FAD hrs - Melrose Park, IL
with Andy Sias

OVERVIEW:This training course provides the participants with an overview of 1-to-1 mini-split products including installation requirements, operating characteristics and a general overview of service and troubleshooting procedures.
WHO SHOULD ATTEND:The target audience includes HVAC technicians and installers. Attendees should have a general understanding of air conditioning systems, refrigerants, installation and service procedures.
REQUIRED TOOLS: torque wrench, R-410A flaring tool, reemer, pipe cutter, 2 adjustable wrenches, electrical meter, and basic hand-tools
OUTLINE:
- Introduction of product (including models, capacities, voltages, etc.)
- Application of R-410a refrigerant
- Installation requirements and procedures
- Operating characteristics
- Fault codes
- Servicing and Diagnostic procedures
- Refrigerant piping lengths and charging procedures
- Installation wiring
This classes qualifies for 4 "FAD Distributor" hours for the dealer and 4 NATE hours for the technician.
NATE course ID# 8532-0022, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Certified HVAC Pro, Efficiency Analyst, Gas Heating Install, Gas Heating Service, HVAC Performance Verifier, Light Comm Refrig Install, Light Comm Refrig Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.