Filter by Category
NATE
A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, Elite, & ComEd hrs - Melrose Park, IL
with Dave Herman
This course offers familiarization of the troubleshooting and installation manuals followed by a hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.
Please bring hand tools, volt or multi-meter, R-454B & R-410A refrigerant gauges, and pressure gauge (magnahelic or monometer).
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Economizer Basics & Setup for Honeywell JADE & Siemens Climatix-ECO (hands-on) - NATE, FAD, & Elite hrs - Libertyville, IL
with Ryan Hoger
Economizers have been increasingly required by energy code but many technicians have a set it and forget attitude about these devices. Sometimes they can be simple applications, but other times things can bite you.
This course will examine the following:
1. Technology Overview
2. Dry bulb vs. Enthalpy
3. IECC Code Requirements (including local law)
4. Typical Energy Savings
5. CO2-based Demand Controlled Ventilation (DCV)
6. Honeywell JADE and Siemens Climatix-ECO Controller Wiring
7. Hands-on Setup and Configuration of JADE on the workbench
8. Siemens Climatix-ECO Setup and Configuration
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0009
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Gas Heat Install, Gas Heat Service, Light Commercial Install, Light Commercial Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, Elite, & ComEd hrs - Melrose Park, IL
with Dave Herman
Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.
This course will cover the fully variable R-454B & R-410A units, as well as the 5-stage R-410A units.
These units are very efficient under part load conditions and use variable speed inverter-driven scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.
These units feature low turndown, high-efficiency, smooth start operation, and sound levels as low as 55dBA. The fully varaible units should be used with a communicating control.
This class will specifically cover:
- Proper application & installation
- Configuration of Infinity/Evolution control
- Refrigerant charging procedure using controller
- Required maintenance
- Troubleshooting & Alarm Codes
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.
NATE course ID# 8532-0016
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, Elite, & ComEd hrs - South Bend, IN
with Dave Herman
Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.
This course will cover the fully variable R-454B & R-410A units, as well as the 5-stage R-410A units.
These units are very efficient under part load conditions and use variable speed inverter-driven scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.
These units feature low turndown, high-efficiency, smooth start operation, and sound levels as low as 55dBA. The fully varaible units should be used with a communicating control.
This class will specifically cover:
- Proper application & installation
- Configuration of Infinity/Evolution control
- Refrigerant charging procedure using controller
- Required maintenance
- Troubleshooting & Alarm Codes
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.
NATE course ID# 8532-0016
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Evolution Connex / Infinity Touch / Ion Controllers (hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL
with Ryan Hoger
This is a hands-on class with 2-3 students per system. The class will cover the functionality of the Evolution, Infinity, and Ion communicating touch screen controls. We will also discuss unique installation requirements as related to zoning systems, variable speed outdoor units, and modulating gas valves.
Topics will include:
-Wiring and commissioning
-Service settings and adjustments
-Wi-Fi setup
-Advanced, smart setback
-Real-time weather display
-Website management tool
-Mobile app usage
This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.
NATE course ID# 8532-0002
NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Ht Pump Install, Ht Pump Service, Gas Heating Install, Gas Heating Service, Hydronics Install, Hydronics Service
-------------------------------------------------------------------------------
CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class. Refunds are available (with a 15% processing fee) up to 72 hours before the start of class. You may also substitute a student from the same company (without penalty) at any time.
Will run
Duct & Envelope Tightness (DET) Certification (hands-on) - NATE, FAD, Elite, & BPI hrs - Melrose Park, IL
with Joe Konopacki
Details and registration for this class are at: https://www.eventbrite.com/e/duct-envelope-tightness-det-verifier-earn-8-bpi-8-nate-ces-melrose-tickets-1980289367807
This classes qualifies for 8 NATE hours and 8 BPI hours for the technician plus 8 "FAD Distributor" or "Elite Distributor" hours for the dealer.