Your browser is not optimized for viewing this website.

More information »

TEC & Excelsior Training

Filter by Category



NATE

A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, & Elite hrs - Lansing, IL

$75

with Dave Herman

Calendar May 8, 2025 at 8 am

Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.

This course will cover the 24/26 SEER fully variable units and the 5-stage units. Each student will also have the opportunity to practice connecting their mobile app to the condensing unit via Bluetooth.

These units are very efficient under part load conditions and use a variable speed inverter-driver scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.

These units feature low turndown (25-100%), high-efficiency, smooth start operation, and sound levels as low as 55dBA. The 5-stage units can can work with a communicating control for 5 stage operation or a standard thermostat for 2 stage functionality.  The fully varaible units must be used with a communicating control.

This class will specifically cover:

  • Proper application & installation 
  • Configuration of Infinity/Evolution control
  • Refrigerant charging procedure using controller
  • Required maintenance
  • Troubleshooting & Alarm Codes

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.

NATE course ID# 8532-0016

NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, & Elite hrs - Melrose Park, IL

$75

with Dave Herman

Calendar May 9, 2025 at 8 am

This course offers a 1 hour familiarization of the troubleshooting and installation manuals followed by a 3 hour hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.

Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.

NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

A/C & Heat Pump 101: Install, Charging, & Service (hands-on) - NATE, FAD, & Elite hrs - Lansing, IL

$75

with Dave Herman

Calendar May 14, 2025 at 8 am

This course offers a 1 hour familiarization of the troubleshooting and installation manuals followed by a 3 hour hands-on training session. The lab work will include maintenance, start-up, troubleshooting procedures of residential condensing units and heat pumps. Students will be working on fully function split systems in the lab area.

Please bring hand tools, volt or multi-meter, R-410a refrigerant gauges, and pressure gauge (magnahelic or monometer).

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.

NATE course ID# 8532-0001, NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Ht Pump Install, Ht Pump Service, Gas Heating Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

A/C & Heat Pump 102: Variable Speed Inverter Install & Service - NATE, FAD, & Elite hrs - Melrose Park, IL

$75

with Dave Herman

Calendar May 16, 2025 at 8 am

Students MUST first attend A/C & Heat Pump 101 or have instructor approval to skip into this more advanced class.

This course will cover the 24/26 SEER fully variable units and the 5-stage units. Each student will also have the opportunity to practice connecting their mobile app to the condensing unit via Bluetooth.

These units are very efficient under part load conditions and use a variable speed inverter-driver scroll and rotary compressors. The intended audience of this particular class is installers and service technicians.

These units feature low turndown (25-100%), high-efficiency, smooth start operation, and sound levels as low as 55dBA. The 5-stage units can can work with a communicating control for 5 stage operation or a standard thermostat for 2 stage functionality.  The fully varaible units must be used with a communicating control.

This class will specifically cover:

  • Proper application & installation 
  • Configuration of Infinity/Evolution control
  • Refrigerant charging procedure using controller
  • Required maintenance
  • Troubleshooting & Alarm Codes

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD or Elite Distributor" hours for the dealer.

NATE course ID# 8532-0016

NATE credit received through this course is associated with the following specialties: A/C Install, A/C Service, Air Distribution Install, Air Distribution Service, Air to Air Heat Pump Install, Air to Air Heat Pump Service, Certified HVAC Professional, Efficiency Analyst Senior, Gas Heating (Air) Install, Gas Heating (Air) Service, HVAC Performance Verifier, Light Commercial Refrigeration Install, Light Commercial Refrigeration Service

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

3 to 27 ton RTUs with Vane Axial Fans - NATE, FAD, & Elite hrs - Melrose Park, IL

$65

with Neil Stoeger

Calendar May 21, 2025 at 8 am

Times are changing and the current code requirements for high IEERs are driving the market to use Staged Air Volume (SAV) in place of the traditional constant volume systems.

Smaller units using vane axial fans with ECM motors are standard now, so we will cover this type of RTU from Carrier (EcoBlue), Bryant (Axion), and ICP (X-Vane).  This exclusive technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. This RTU includes the industry’s first belt-less direct-drive vane axial fan for rooftop units, a new control board and coil technology, permanently lubricated motor bearings, tool-less filter access doors, and more.

Technicians need to know how to properly install, setup, and service all of these units, as they are now the standard RTUs in the market.

Topics covered include installation, start-up, and troubleshooting. We will discuss standard RTUs, ECM controlled SAV RTUs, airflow setup, vane axial fans, humidimizer, and economizers.

We will focus on Bryant, Carrier, & ICP SAV equipment in the 3 thru 27 ton range.

This classes qualifies for 4 NATE hours for the technician plus 4 "FAD Distributor" or "Elite Distributor" hours for the dealer.

NATE course ID# 8532-0014

 

-------------------------------------------------------------------------------

CANCELLATION POLICY - To cancel out of a class, please email ryan.hoger@tecmungo.com with your name and the date of the class.  Refunds are available (with a 15% processing fee) up to 72 hours before the start of class.  You may also substitute a student from the same company (without penalty) at any time.

Duct & Envelope Tightness (DET) Certification (hands-on) - NATE, FAD, Elite, & BPI hrs - Melrose Park, IL
Online Registration Unavailable

Duct & Envelope Tightness (DET) Certification (hands-on) - NATE, FAD, Elite, & BPI hrs - Melrose Park, IL

$330

with Joe Konopacki

Calendar Jun 4, 2025 at 7:30 am

Details and registration for this class are at: https://www.insightpsinc.com/bpi-building-analyst-training/

This classes qualifies for 8 NATE hours and 8 BPI hours for the technician plus 8 "FAD Distributor" or "Elite Distributor" hours for the dealer.





Forgot password?
Staff Log In